[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-fire-law-028":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-消防法規概要-028","fire-110-1-fire-law-028",110,1,28,"依各類場所消防安全設備設置標準規定，下列場所何者屬於乙類場所？",{"A":16,"B":17,"C":18,"D":19},"日間型精神復健機構","榮譽國民之家","托嬰中心","啟明、啟智、啟聰等特殊學校","A",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第十二條之用途分類，尤其是甲類場所與乙類場所的分界。\n【正解理由】第十二條第二款第六目逐字列有「辦公室、靶場、診所、長期照顧服務機構（限社區式之建築物使用類組屬H-2之日間照顧、團體家屋及小規模多機能）、日間型精神復健機構、兒童及少年心理輔導或家庭諮詢機構……」，日間型精神復健機構明文歸入乙類場所，故選 A。\n【逐項排除】\n(A) 日間型精神復健機構列於第十二條第二款第六目，與辦公室、診所同目，屬乙類場所，為本題應選者。\n(B) 榮譽國民之家列於第十二條第一款第六目，與醫院、療養院並列，屬甲類場所。\n(C) 托嬰中心列於第一款第六目之「兒童及少年福利機構（限托嬰中心、早期療育機構、有收容未滿二歲兒童之安置及教養機構）」，屬甲類場所。\n(D) 啟明、啟智、啟聰等特殊學校列於第一款第六目末段，屬甲類場所；第二款第三目所稱的是學校教室，兩者不可混為一談。\n【記憶點】收容者須人協助避難者（住宿、養護、特殊學校）歸甲類；日間型、能自行離開者歸乙類。","用途分類不是背誦遊戲，它直接決定應設設備的面積門檻。以火警自動警報設備為例，第十九條第一款規定五層以下之建築物供第十二條第一款及第二款第十二目所列場所使用，任何一層之樓地板面積在三百平方公尺以上即應設；供同條第二款（第十二目除外）至第四款所列場所使用者，門檻放寬到任何一層五百平方公尺。自動撒水設備亦同：第十七條第一款規定十層以下建築物之樓層供第十二條第一款第一目所列場所使用，樓地板面積合計三百平方公尺以上應設，供同款其他各目及第二款第一目所列場所使用者則為一千五百平方公尺。同一空間被認定為甲類或乙類，應設門檻可能相差五倍。\n第一款第六目那一整串機構還有兩項專屬規定：第二十二條之一規定醫院、療養院、榮譽國民之家、長期照顧服務機構、老人福利機構、護理機構、身心障礙福利機構等場所應設置一一九火災通報裝置；第十七條第一項第九款規定榮譽國民之家、長期照顧服務機構、老人福利機構、護理機構、身心障礙福利機構等使用之場所應設自動撒水設備，同條第三項並容許其樓地板面積合計未達一千平方公尺者，設置水道連結型自動撒水設備或與現行法令同等以上效能之滅火設備。\n易混淆對照有三組：一是精神復健機構，日間型在第二款第六目、住宿型在第二款第七目與集合住宅、寄宿舍同列，兩者都在乙類；二是護理機構中的精神護理之家列在第一款第六目屬甲類，與精神復健機構分屬不同款，名稱極像而類別不同；三是托嬰中心屬甲類，幼兒園卻在第二款第十二目屬乙類，且幼兒園在第十九條第一款被特別與甲類並列拉回三百平方公尺的門檻。第一百五十九條第五款所列得免設避難器具的機構清單，也是照第一款第六目那一串開的，可一併對照記憶。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-fire-law-027","依各類場所消防安全設備設置標準規定，自動撒水設備得依實際情況需要選擇適當型式設置。但下列何種場所應設開放式？",27,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-fire-law-029","有一室外儲槽，其容量為 9000 公秉，依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，設有防火水幕，下列敘述何者正確？",29,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-fire-law-026","依各類場所消防安全設備設置標準規定，裝設火警自動警報設備之建築物，其火警分區劃定，下列敘述何者正確？",26,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-fire-law-030","可燃性高壓氣體儲存場所防爆牆分為鋼筋混凝土製、混凝土空心磚製及鋼板製等三種，並應設置於堅固基礎上，強度應能承受可能預料之氣體爆炸衝擊，有關混凝土空心磚製防爆牆之規定，下列敘述何者正確？",30,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-fire-law-025","某場所室內高度為 16 公尺，依各類場所消防安全設備設置標準規定，下列何者為可選擇之探測器種類？①定溫式特種 ②差動式分布型 ③光電式局限型一種 ④火焰式",25,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-fire-law-031","有關標示設備之規定，下列敘述何者正確？",31,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-fire-law-028",111,"可燃性高壓氣體儲存場所防爆牆，其鋼筋混凝土經過 28 日養生後之抗壓強度（kgf\u002Fcm2），應為多少以上？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-fire-law-028",109,"依各類場所消防安全設備設置標準，有關裝設瓦斯漏氣火警自動警報設備之規定，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-fire-law-028",108,"依可燃性高壓氣體儲存場所防爆牆設置基準規定，防爆牆分為鋼筋混凝土製、混凝土空心磚製及鋼板製等三種，並應設置於堅固基礎上，其強度應能承受可能預料之氣體爆炸衝擊。下列有關其構造規定何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-fire-law-028",107,"依公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之規定，液化石油氣販賣場所儲放液化石油氣，總儲氣量不得超過 X 公斤，超過部分得設容器保管室儲放之，但總儲氣量以 Y 公斤為限。X、Y 分別為多少？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-fire-law-028",106,"依可燃性高壓氣體儲存場所防護牆設置基準規定，鋼筋混凝土製防護牆，其厚度應在多少 mm 以上？",1785123158038]