[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-110-1-fire-law-039":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-消防法規概要-039","fire-110-1-fire-law-039",110,1,39,"依建築技術規則建築設計施工編規定，有關建築技術用語之定義，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"地下層：地板面在基地地面以下之樓層。但天花板高度有三分之一以上在基地地面上者，視為地面層","總樓地板面積：建築物各層包括地下層、屋頂突出物及夾層等樓地板面積之總和","居室：供居住、工作、集會、娛樂、烹飪等使用之房間，包括門廳、走廊、樓梯間、衣帽間均稱居室","集合住宅：具有共同基地及共同空間或設備。並有二個住宅單位以上之建築物","B",null,[],false,"本題考點：建築技術規則建築設計施工編建築技術用語定義中之地下層、總樓地板面積、居室與集合住宅。\n【正解理由】依建築技術規則建築設計施工編建築技術用語定義,總樓地板面積指建築物各層包括地下層、屋頂突出物及夾層等樓地板面積之總和,(B) 與定義相符,故選 B。此定義在消防上直接決定應設設備門檻,如《設置標準》第 24 條以總樓地板面積一千平方公尺以上建築物之居室應設緊急照明設備。\n【逐項排除】\n(A) 地下層之除外門檻是天花板高度有三分之二以上在基地地面上者始視為地面層,(A) 誤寫為三分之一,放寬了認定標準。\n(B) 總樓地板面積確實把地下層、屋頂突出物及夾層一併計入,為本題應選者。\n(C) 居室指供居住、工作、集會、娛樂、烹飪等使用之房間;門廳、走廊、樓梯間、衣帽間屬通行或附屬空間,不視為居室,(C) 將其納入居室,與定義不合。\n(D) 集合住宅須具共同基地及共同空間或設備,並有三個住宅單位以上,(D) 誤為二個住宅單位。\n【記憶點】總樓地板面積「地下層、屋突、夾層都要算」;地下層看三分之二,集合住宅看三單位。","四個用語各有出題陷阱。地下層以「天花板高度有三分之二以上在基地地面上者,視為地面層」為除外,關鍵在三分之二而非二分之一或三分之一;一旦判定為地下層,消防上的影響極大——《設置標準》第 49 條免裝撒水頭之區劃分隔規定,明文把地下層、無開口樓層及第十一層以上之樓層排除在適用之外,第 190 條免設排煙設備亦以第十層以下各樓層(地下層除外)為前提。\n總樓地板面積之所以要把地下層、屋頂突出物及夾層一併計入,是因為它是量體規模的指標:量體愈大,火載量與收容人員愈多。第 24 條緊急照明設備以總樓地板面積一千平方公尺以上建築物之居室為對象,第 29 條緊急電源插座以總樓地板面積一千平方公尺以上之地下建築物為對象,計算基準抓錯即整棟判定錯誤。\n居室的定義是「人會停留使用」的房間,門廳、走廊、樓梯間、衣帽間屬通行與附屬空間。此區辨直接連動應設設備:第 24 條前四款以居室為對象,第五款才另把「自居室通達避難層所須經過之走廊、樓梯間、通道及其他平時依賴人工照明部分」納入,可見法規把居室與通行空間分開處理;第 28 條排煙設備第二款同樣以「樓地板面積在一百平方公尺以上之居室」起算。\n集合住宅須三個住宅單位以上,與二戶並列之雙併住宅有別。記憶上可串成「地下三分之二、集合三單位、總面積三合一(地下層、屋突、夾層)」,一次收攏本題四個選項。最後補一個易錯點:屋頂突出物雖須計入總樓地板面積,卻不當然計為一個樓層,與夾層超過門檻即視為另一樓層的效果不同,兩者的判定基準常在同一題內交錯設問,務必分辨清楚。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-fire-law-038","依建築技術規則建築設計施工編規定，有關防火門構造等相關規定，下列敘述何者正確？",38,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-fire-law-040","依建築技術規則建築設計施工編規定，下列何者屬無窗戶居室？",40,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-fire-law-037","有關二氧化碳滅火設備使用之各種標示規格，下列敘述何者正確？",37,{"webId":41,"stem":42,"number":12,"year":43,"session":12},"fire-111-1-fire-law-001","依消防法及消防法施行細則之規定，下列那一個場所應由管理權人，遴用防火管理人並責其製定消防防護計畫報請消防機關核備？",111,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-fire-law-036","依建築技術規則建築設計施工編規定，夾層係指夾於樓地板與天花板間之樓層；同一樓層內夾層面積之和，超過多少平方公尺，視為另一樓層？",36,{"webId":49,"stem":50,"number":51,"year":43,"session":12},"fire-111-1-fire-law-002","有關液化石油氣零售業者、專業機構、容器製造、輸入業者或容器檢驗機構之相關規定，下列敘述何者錯誤？",2,[53,56,60,64,68],{"webId":54,"year":43,"stem":55,"number":13},"fire-111-1-fire-law-039","避難器具裝置在固定部上之固定器具材料如為鋼材，其鋼索之容許拉伸應力為剪斷荷重的多少比例？",{"webId":57,"year":58,"stem":59,"number":13},"fire-109-1-fire-law-039",109,"依各類場所消防安全設備設置標準之規定，以防護區域每平方公尺每分鐘放水量來看，儲存可燃物場所設置放水型撒水頭是一般場所要求的幾倍？",{"webId":61,"year":62,"stem":63,"number":13},"fire-108-1-fire-law-039",108,"依建築技術規則建築設計施工編規定，下列何者不屬於「無窗戶居室」？",{"webId":65,"year":66,"stem":67,"number":13},"fire-107-1-fire-law-039",107,"依建築技術規則建築設計施工編之規定，常時關閉式防火門之單一門扇面積不得超過多少平方公尺？",{"webId":69,"year":70,"stem":71,"number":13},"fire-106-1-fire-law-039",106,"依據建築技術規則建築設計施工編規定，下列用語定義何者正確？",1785123158154]