[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-fire-science-016":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"火災學概要","fire-science","火災學 · Fire Science","火災學",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-火災學概要-016","fire-110-1-fire-science-016",110,1,16,"市面上販售的 ABC 乾粉滅火器內充填的乾粉滅火藥劑主要成分為：",{"A":16,"B":17,"C":18,"D":19},"碳酸氫鉀（KHCO3）及尿素（CH4N2O）化合物","碳酸氫鈉（NaHCO3）","碳酸氫鉀（KHCO3）","磷酸二氫銨（NH4H2PO4）","D",null,[],false,"本題考點：乾粉滅火藥劑四種類型的主成分，以及能適用 A、B、C 三類火災者為何。\n【正解理由】乾粉依主成分分為四種：第一種碳酸氫鈉、第二種碳酸氫鉀、第三種磷酸二氫銨、第四種碳酸氫鉀與尿素的反應物。其中僅第三種磷酸二氫銨受熱後生成偏磷酸而在固體表面形成黏著性覆膜，能抑制 A 類深層悶燒，因而通稱多效能乾粉或 ABC 乾粉，市售 ABC 乾粉滅火器所充填者即為此成分，故選 D。\n【逐項排除】\n(A) 碳酸氫鉀與尿素化合物為第四種乾粉，滅火效力高但適用 B、C 類火災，非 ABC 型。\n(B) 碳酸氫鈉為第一種乾粉，白色，適用 B、C 類火災，對 A 類深層火無覆膜效果。\n(C) 碳酸氫鉀為第二種乾粉，俗稱紫鉀，滅火效力約為第一種的兩倍，但同樣僅適用 B、C 類。\n(D) 磷酸二氫銨為第三種乾粉，兼具負觸媒抑制與覆膜隔絕作用，可用於 A、B、C 三類火災，敘述正確。\n【記憶點】一鈉、二鉀、三磷酸銨、四鉀加尿素；四種之中只有第三種打得了 A 類。","乾粉的滅火機制有三層：最主要是負觸媒作用，粉粒受熱釋出的鹼金屬離子捕捉燃燒連鎖反應中的氫氧自由基與氫自由基，使鏈反應中斷；其次是分解吸熱與生成二氧化碳、水蒸氣造成的冷卻與稀釋；第三是粉體形成的遮蔽作用，阻隔火焰對燃料表面的輻射回饋。四種乾粉在前兩層機制上大同小異，真正拉開差距的是第三種特有的覆膜效果。\n磷酸二氫銨的分解路徑是本考點的核心：約 190 ℃ 起分解放出氨與磷酸，約 260 ℃ 進一步脫水生成偏磷酸（HPO₃），溫度更高時聚合成聚偏磷酸並以熔融態黏附於燃燒中的固體表面，形成隔絕氧氣的玻璃狀薄膜，使木材、紙張、纖維等 A 類可燃物的深層悶燒無法持續。碳酸氫鹽類分解後只生成氣體與碳酸鹽粉末，落在物體表面即散失，因此無法對付 A 類火災的餘燼復燃。\n選用上的對照也常入題：第四種乾粉（碳酸氫鉀與尿素的反應產物）粉粒受熱會爆裂成更多微粒，比表面積驟增，單位重量滅火效力最高，多用於大型油類火災；第二種紫鉀對 B 類的效力約為第一種的兩倍；第一種價格最低、應用最廣。另須注意乾粉與蛋白泡沫併用會破壞泡沫層，兩者原則上不同時使用；乾粉對精密電子設備與資料機房有粉塵污損問題，該類場所多改用二氧化碳或惰性氣體滅火設備。\n滅火器本體的分類則是另一組易混題：依加壓方式分為加壓式與蓄壓式，蓄壓式附有指示壓力表可直接目視判讀，加壓式須另設加壓用氣體容器。命題時常把「藥劑種類」與「加壓方式」兩組概念混編成選項，作答時先辨明題目問的是成分還是構造。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-fire-science-015","下列有關液化天然氣（LNG）與液化石油氣（LPG）之比較，何者正確？",15,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-fire-science-017","下列惰性氣體類海龍替代滅火藥劑中，何者的比重小於 1？",17,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-fire-science-014","自然發火性物質中的原棉，主要是因為下列何種熱之蓄積而發火？",14,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-fire-science-018","根據「危害物質災害現場搶救標準作業程序」之規定，其首要工作為何？",18,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-fire-science-013","有一開口面積為 10.0 m2，開口高度為 1.44 m 之居室，當其發生火災而形成通風控制燃燒時，根據 P. H. Thomas 之研究結果，則燃燒速度為多少 kg\u002Fmin？",13,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-fire-science-019","當發生危害物質災害時，為降低對民眾及搶救人員的危害，應迅速劃定管制區域，下列區域何者一般以黃色標示？",19,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-fire-science-016",111,"比較積污導電與金原現象之差異，下列何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-fire-science-016",109,"假設建築物外部風速為 10 m\u002Fs，風壓係數為 0.6，空氣密度為 1.0 kg\u002Fm3，其對迎風面建築物所產生的風壓約為？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-fire-science-016",108,"某發生火警的大樓，室內外溫度分別為 800℃與 20℃，中性帶位於 4 樓；6 樓的內外壓差為 60 Pa，若不考慮外部風等其他因素，則 8 樓的內外壓差約為若干 Pa？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-fire-science-016",107,"下列何者為海龍替代品滅火藥劑 FE-13 之分子式？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-fire-science-016",106,"下列有關粉塵爆炸之敘述，何者錯誤？",1785123162388]