[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-110-1-water-chemical-001":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":26,"sameNumber":52,"hasEssay":25},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":12,"stem":13,"options":14,"answer":19,"answerNote":20,"images":21,"imagesPending":22,"lawTimestamp":11,"explanation":23,"explanationDeep":24,"freq":12,"indexable":25},"fire-110-1-水與化學系統消防安全設備概要-001","fire-110-1-water-chemical-001",110,1,"公共危險物品等場所消防設計及消防安全設備，電氣設備使用之處所，每多少平方公尺（含未滿）應設置第五種滅火設備一具以上？",{"A":15,"B":16,"C":17,"D":18},"20","50","100","200","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第四編就公共危險物品等場所「電氣設備使用處所」應設第五種滅火設備的面積級距。\n【正解理由】依《各類場所消防安全設備設置標準》第 204 條，條文明定「電氣設備使用之處所，每一百平方公尺（含未滿）應設置第五種滅火設備一具以上」；同標準第 197 條第一項第五款並界定第五種滅火設備係指滅火器、水桶、水槽、乾燥砂、膨脹蛭石或膨脹珍珠岩。題目所問即為此一面積級距，故選 C。\n【逐項排除】\n(A) 20 平方公尺：第 204 條無此級距，第四編各條所定面積級距為五十、七十五、一百、一百五十平方公尺，並無二十平方公尺之規定。\n(B) 50 平方公尺：五十平方公尺見於第 199 條第一款「外牆為非防火構造者，總樓地板面積每五十平方公尺（含未滿）有一滅火效能值」，講的是滅火效能值核算，不是電氣設備處所的設置具數。\n(C) 100 平方公尺：與第 204 條條文逐字相符，為正解。\n(D) 200 平方公尺：第四編條文所列面積級距並無二百平方公尺，該數值不見於本條。\n【記憶點】電氣設備使用處所「每 100 平方公尺（含未滿）一具第五種滅火設備」。","第 204 條位於《各類場所消防安全設備設置標準》第四編【公共危險物品等場所消防設計及消防安全設備】，該編僅適用於公共危險物品及可燃性高壓氣體場所；辦公室、停車場、百貨等一般場所另依第二編、第三編規定，兩編數值不同，不得互套。第 204 條規範的是「電氣設備使用之處所」，例如變電室、發電機室、配電盤室，因其火災屬電氣火災，故要求就地備置可立即取用的第五種滅火設備。\n\n第五種滅火設備的內涵見同標準第 197 條第一項第五款：滅火器、水桶、水槽、乾燥砂、膨脹蛭石或膨脹珍珠岩。同項並定第一種為室內或室外消防栓設備、第二種為自動撒水設備、第三種為水霧、泡沫、二氧化碳或乾粉滅火設備、第四種為大型滅火器。乾燥砂、膨脹蛭石與膨脹珍珠岩之所以列入，是因為部分公共危險物品遇水會激烈反應，只能以覆蓋方式窒息。\n\n第五種滅火設備的「數量」另有一套核算邏輯，與本題的「每一百平方公尺一具」是兩回事，考試最常在此設陷。第 199 條規定最低滅火效能值：製造或處理場所之建築物外牆為防火構造者，總樓地板面積每一百平方公尺（含未滿）有一滅火效能值，非防火構造者每五十平方公尺；儲存場所之建築物外牆為防火構造者每一百五十平方公尺，非防火構造者每七十五平方公尺；室外具連帶使用關係之附屬設施，以水平最大面積為樓地板面積並準用外牆為防火構造者核算；另公共危險物品每達管制量之十倍（含未滿）有一滅火效能值。\n\n相關考點連結：第 202 條就一般滅火困難場所規定第五種滅火設備之滅火效能值須在最低滅火效能值五分之一以上；第 203 條就其他滅火困難場所要求達最低滅火效能值以上，已設第一種至第四種滅火設備之一者，於有效防護範圍內得減至五分之一以上，並明定地下儲槽場所應設置第五種滅火設備二具以上；第 206-1 條則就爆竹煙火製造、儲存、販賣場所另定應設第五種滅火設備。",true,[27,32,36,40,44,48],{"webId":28,"stem":29,"number":30,"year":31,"session":12},"fire-109-1-water-chemical-040","儲槽規定設置補助泡沫消防栓時，下列敘述何者錯誤？",40,109,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-water-chemical-002","連結送水管之中繼幫浦放水測試時，應從送水口以送水設計壓力送水，並以口徑 21 公厘瞄子在最頂層測試，其放水壓力不得小於 X kgf\u002Fcm2，且放水量不得小於 Y L\u002Fmin。X、Y 分別為何？",2,{"webId":37,"stem":38,"number":39,"year":31,"session":12},"fire-109-1-water-chemical-039","公共危險品等場所中，所設置之室外消防栓設備，其緊急電源之供電容量應供其有效動作多久以上？",39,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-water-chemical-003","公共危險物品等場所消防設計及消防安全設備，顯著滅火困難場所之室外儲槽場所，儲存硫磺，應設置何種滅火設備？",3,{"webId":45,"stem":46,"number":47,"year":31,"session":12},"fire-109-1-water-chemical-038","消防專用蓄水池之設置規定，下列何者正確？",38,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-water-chemical-004","下列有關室內消防栓設備之規定，何者錯誤？",4,[53,57,60,64,68],{"webId":54,"year":55,"stem":56,"number":12},"fire-111-1-water-chemical-001",111,"依各類場所消防安全設備設置標準規定，下列何種場所不需設置室外消防栓設備？",{"webId":58,"year":31,"stem":59,"number":12},"fire-109-1-water-chemical-001","下列場所何者未達依法應設置滅火器之條件？",{"webId":61,"year":62,"stem":63,"number":12},"fire-108-1-water-chemical-001",108,"在應設置室內消防栓設備之場所，但設有室外消防栓設備時，在第一層水平距離 X 公尺以下、第二層步行距離 Y 公尺以下有效滅火範圍內，室內消防栓設備限於第一層、第二層免設。X、Y 分別為何？",{"webId":65,"year":66,"stem":67,"number":12},"fire-107-1-water-chemical-001",107,"撒水頭之設置位置規定中，撒水頭迴水板下方 A 公分內及水平方向 B 公分內，應保持淨空間，不得有障礙物，其中 A、B 分別為下列何者？",{"webId":69,"year":70,"stem":71,"number":12},"fire-106-1-water-chemical-001",106,"依 NFPA 2001 之規定，潔淨式氣體滅火系統於一般場所之藥劑放射時間（達設計濃度 95%之時間），下列何者錯誤？",1785123166517]