[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-110-1-water-chemical-004":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":51,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-水與化學系統消防安全設備概要-004","fire-110-1-water-chemical-004",110,1,4,"下列有關室內消防栓設備之規定，何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"低度危險工作場所應設置第一種消防栓","老人福利機構可選擇設置第二種消防栓","第一種消防栓箱內應配置口徑 25 毫米消防栓","第一種消防栓箱內應配置口徑 38 毫米或 50 毫米之消防栓一個","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》中第一種與第二種室內消防栓之區辨，重點在箱內瞄子與管牙口徑及得設第二種之場所。\n【正解理由】依《各類場所消防安全設備設置標準》關於室內消防栓設備之規定，第一種消防栓箱內應配置口徑 38 毫米或 50 毫米之消防栓一個、水帶及瞄子，屬雙人操作、放水量與射程較大之型式；口徑 25 毫米者為第二種消防栓，採保形水帶可單人操作。本題問「錯誤」者，選項將 25 毫米歸入第一種，與規定不符，故選 C。\n【逐項排除】\n(A) 低度危險工作場所依規定設置第一種消防栓，敘述與應設型式之規定相符，並非錯誤選項。\n(B) 老人福利機構等避難弱者使用之場所，因現場人力多為女性或高齡照服人員，法規允許選擇操作較輕便的第二種消防栓，敘述正確。\n(C) 第一種消防栓箱內配置口徑 25 毫米消防栓，把第二種的口徑套在第一種上，為本題唯一與規定牴觸的敘述，是正解。\n(D) 第一種消防栓箱內配置口徑 38 毫米或 50 毫米之消防栓一個，與條文所定規格一致，敘述正確。\n【記憶點】第一種粗管 38／50 毫米、雙人操作；第二種細管 25 毫米、單人可用，口徑數字別對調。","室內消防栓分為第一種與第二種，制度設計上是「性能」與「可操作性」的取捨。第一種源自早期以雙人操作為前提的設計，配置 38 毫米或 50 毫米管牙與麻織或襯膠水帶，放水量與射程大，適合火載量高、需要較強射水能力的工作場所；缺點是水帶必須先完全展開、反作用力大，未受訓者難以獨力操作。第二種則採 25 毫米口徑與保形水帶，水帶本身具形狀記憶可邊拉邊放水，單人即可操作，放水量較小但反應迅速，適合初期滅火與使用人不特定或體力受限的場所。\n\n主要規格數值可整理成對照表以利記憶。第一種：口徑 38 或 50 毫米、瞄子放水壓力介於約 1.7 kgf\u002Fcm² 以上 7 kgf\u002Fcm² 以下、放水量每分鐘 130 公升以上、水平距離 25 公尺以下、水源容量以同時使用二支計算。第二種：口徑 25 毫米、放水壓力約 2.5 kgf\u002Fcm² 以上 7 kgf\u002Fcm² 以下、放水量每分鐘 60 公升以上、水平距離 15 公尺以下。兩者共同點是最高使用壓力均不得超過 7 kgf\u002Fcm²，超過時須設減壓措施，避免瞄子反作用力過大導致使用者受傷。壓力單位換算亦是常考點：1 kgf\u002Fcm² ≈ 0.098 MPa ≈ 10 公尺水頭。\n\n設置場所的分流邏輯，是以危險程度與使用人特性為判準。工作場所依火災危險度分為低度、中度、高度三級，危險度較高者要求較強之射水能力；而供避難弱者使用之場所，例如老人福利機構、幼兒園、醫院病房等，法規則傾向允許採用操作門檻較低的型式，使現場人員在專責消防人力到達前即能發揮初期滅火功能。\n\n易混淆概念對照：室內消防栓與室外消防栓的口徑、水源容量、加壓送水裝置揚程計算完全不同，室外消防栓口徑更大且以建築物外周布置；另補助撒水栓雖外觀近似第二種消防栓，但屬自動撒水設備之一環，與室內消防栓設備分屬不同條文，不可混淆。\n\n相關考點連結：本主題常與水源容量計算、加壓送水裝置全揚程公式、消防栓箱標示與紅色啟動表示燈之規定合併命題。",true,[28,32,36,40,44,47],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-water-chemical-003","公共危險物品等場所消防設計及消防安全設備，顯著滅火困難場所之室外儲槽場所，儲存硫磺，應設置何種滅火設備？",3,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-water-chemical-005","消防幫浦加壓送水裝置之啟動用水壓開關裝置，下列規定何者正確？",5,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-water-chemical-002","連結送水管之中繼幫浦放水測試時，應從送水口以送水設計壓力送水，並以口徑 21 公厘瞄子在最頂層測試，其放水壓力不得小於 X kgf\u002Fcm2，且放水量不得小於 Y L\u002Fmin。X、Y 分別為何？",2,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-water-chemical-006","有關撒水頭位置裝置之規定，下列敘述何者錯誤？",6,{"webId":45,"stem":46,"number":12,"year":11,"session":12},"fire-110-1-water-chemical-001","公共危險物品等場所消防設計及消防安全設備，電氣設備使用之處所，每多少平方公尺（含未滿）應設置第五種滅火設備一具以上？",{"webId":48,"stem":49,"number":50,"year":11,"session":12},"fire-110-1-water-chemical-007","依密閉式撒水頭認可基準規定，其中之耐洩漏試驗，係將撒水頭施予多少之靜水壓力，保持 5 分鐘不得有漏水現象？",7,[52,56,60,64,68],{"webId":53,"year":54,"stem":55,"number":13},"fire-114-1-water-chemical-004",114,"依各類場所消防安全設備設置標準規定，鹵化烴滅火設備，蓄壓式儲存容器儲存 HFC-227ea、 FK-5-1-12 之儲存壓力，應以氮氣加壓至 X MPa 以上。加壓式儲存容器，應設置可調整壓力至 Y MPa 之壓力調整裝置。則 X+Y 為多少？",{"webId":57,"year":58,"stem":59,"number":13},"fire-112-1-water-chemical-004",112,"依水道連結型自動撒水設備設置基準之規定，採民生水箱共用式，其配管、配件及閥類之規定，下列敘述何者錯誤？",{"webId":61,"year":62,"stem":63,"number":13},"fire-111-1-water-chemical-004",111,"裝置於舞臺之開放式自動撒水設備，依規定下列何者正確？",{"webId":65,"year":66,"stem":67,"number":13},"fire-109-1-water-chemical-004",109,"供集會堂使用之舞臺，應設置何種自動撒水設備？",{"webId":69,"year":70,"stem":71,"number":13},"fire-108-1-water-chemical-004",108,"密閉乾式或預動式自動撒水設備，下列設置規定何者正確？",1785123166542]