[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-water-chemical-005":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-水與化學系統消防安全設備概要-005","fire-110-1-water-chemical-005",110,1,5,"消防幫浦加壓送水裝置之啟動用水壓開關裝置，下列規定何者正確？",{"A":16,"B":17,"C":18,"D":19},"在啟動用壓力槽上或其近傍應裝設壓力表、啟動用水壓開關及試驗幫浦啟動用之逆止閥","啟動用壓力儲槽應使用口徑 35 mm 以上配管，與幫浦出水側逆止閥之一次側配管連接","啟動用壓力槽之構造應符合危險性機械及設備安全檢查規則之規定","啟動用壓力槽容量應有 110 L 以上","C",null,[],false,"本題考點：消防幫浦加壓送水裝置之啟動用水壓開關裝置，其壓力槽的容量、配管、附屬閥件與構造所應適用的法規。\n【正解理由】依《消防幫浦加壓送水裝置等及配管摩擦損失計算基準》關於啟動用水壓開關裝置之規定，啟動用壓力槽屬承受壓力之容器，其構造應符合《危險性機械及設備安全檢查規則》之規定；四個選項中僅此項與該基準相符，故選 C。\n【逐項排除】\n(A) 壓力槽上或其近傍應裝設的是壓力表、啟動用水壓開關及試驗幫浦啟動用之排水閥，藉排水製造壓降以測試自動啟動；本選項把排水閥誤植為逆止閥。\n(B) 啟動用壓力儲槽應使用口徑二十五毫米以上配管，且與幫浦出水側逆止閥之二次側配管連接，才感測得到系統側的壓力變化；本選項的三十五毫米與一次側兩處均不符。\n(C) 啟動用壓力槽為受壓容器，其構造依危險性機械及設備安全檢查規則檢查，敘述正確，為正解。\n(D) 啟動用壓力槽容量規定為一百公升以上；本選項的一百一十公升非該基準所定數值。\n【記憶點】啟動用壓力槽記「容量 100 L 以上、25 mm 以上配管接逆止閥二次側、附排水閥、構造依危險性機械及設備安全檢查規則」。","啟動用水壓開關裝置是消防幫浦「自動啟動」的核心元件：壓力槽內存有加壓水與壓縮空氣，配管末端一有放水或漏水造成壓力下降，壓力開關即感知而使幫浦啟動。也因為它是壓力容器，其構造被拉到勞動安全法規體系下管理，這正是本題的答題關鍵。選項 A、B、D 三項則是把容量、配管口徑、連接位置與附屬閥件各改動一處而成的典型陷阱寫法。\n\n該裝置的要件可整理成四點：容量一百公升以上；使用口徑二十五毫米以上配管，並與幫浦出水側逆止閥的二次側配管連接；壓力槽上或其近傍裝設壓力表、啟動用水壓開關及試驗幫浦啟動用之排水閥；壓力槽構造應符合危險性機械及設備安全檢查規則。接在逆止閥二次側是設計上的必然——一次側為幫浦側，感測不到系統管路的壓力變化。\n\n檢查面向可與《各類場所消防安全設備檢修及申報作業基準》的室內消防栓設備外觀檢查相互參照：該基準就啟動用水壓開關裝置分為「壓力開關」與「啟動用壓力槽」兩項，前者以目視確認有無變形、損傷等，判定應無變形、損傷；後者以目視確認有無變形、漏水、腐蝕等，並確認壓力表之指示值是否適當正常，判定應無變形、腐蝕、漏水、漏氣及顯著腐蝕，且壓力表之指示值應正常。同一套要領在泡沫滅火設備與水霧滅火設備的自動啟動裝置檢查中同樣沿用，兩者的外觀檢查均以相同圖例確認壓力開關與啟動用壓力槽，並另就火警感知裝置（探測器、密閉式撒水頭）加以確認。\n\n易混淆概念對照：加壓送水裝置的啟動方式除本題的啟動用水壓開關裝置外，尚有由流水檢知裝置或一齊開放閥連動啟動、以及手動啟動裝置直接啟動等型式；記憶時把「壓力槽＋壓力開關＝自動啟動」與「手動啟動開關＝直接操作部」分開，即可避免混淆。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-water-chemical-004","下列有關室內消防栓設備之規定，何者錯誤？",4,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-water-chemical-006","有關撒水頭位置裝置之規定，下列敘述何者錯誤？",6,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-water-chemical-003","公共危險物品等場所消防設計及消防安全設備，顯著滅火困難場所之室外儲槽場所，儲存硫磺，應設置何種滅火設備？",3,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-water-chemical-007","依密閉式撒水頭認可基準規定，其中之耐洩漏試驗，係將撒水頭施予多少之靜水壓力，保持 5 分鐘不得有漏水現象？",7,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-water-chemical-002","連結送水管之中繼幫浦放水測試時，應從送水口以送水設計壓力送水，並以口徑 21 公厘瞄子在最頂層測試，其放水壓力不得小於 X kgf\u002Fcm2，且放水量不得小於 Y L\u002Fmin。X、Y 分別為何？",2,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-water-chemical-008","消防搶救上之必要設備中，連結送水管之送水口設置，下列敘述何者正確？",8,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-water-chemical-005",111,"有關移動式泡沫滅火設備，依各類場所消防安全設備設置標準之規定，下列敘述何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-water-chemical-005",109,"某電信機械室設置二氧化碳全區放射滅火設備，其核算之滅火藥劑量應於多少時間內全部放射完畢？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-water-chemical-005",108,"開放式自動撒水設備之自動及手動啟動裝置，下列設置規定何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-water-chemical-005",107,"泡沫滅火設備使用泡沫噴頭時，每一放射區域之樓地板面積規定應為何？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-water-chemical-005",106,"某一鍋爐房之長寬高分別為 8 m、5 m 及 4 m，若設置全區放射 CO2 滅火設備，其所有開口皆可在放射前自動關閉，試問所需 CO2 藥劑量至少應為多少公斤？",1785123166558]