[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-water-chemical-025":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-水與化學系統消防安全設備概要-025","fire-110-1-water-chemical-025",110,1,25,"自動撒水設備之水源容量規定，若使用側壁型或小區劃型撒水頭時，十層以下樓層在 X 個撒水頭、十一層以上樓層在 Y 個撒水頭繼續放水 20 分鐘之水量以上。X、Y 分別為何？",{"A":16,"B":17,"C":18,"D":19},"X=8；Y=12","X=12；Y=15","X=16；Y=20","X=24；Y=30","A",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 57 條第 3 款，使用側壁型或小區劃型撒水頭時，水源容量應以幾個撒水頭計算。\n【正解理由】依《各類場所消防安全設備設置標準》第 57 條第 3 款，「使用側壁型或小區劃型撒水頭時，十層以下樓層在八個撒水頭、十一層以上樓層在十二個撒水頭繼續放水二十分鐘之水量以上」，即 X＝8、Y＝12，故選 A。\n【逐項排除】\n(A) 正確。八個與十二個正是第 57 條第 3 款針對側壁型、小區劃型撒水頭所定的個數，放水時間同為二十分鐘。\n(B) 錯誤。十二與十五是同條第 1 款表中「十一樓以上建築物、地下建築物」的快速反應型十二個、一般反應型十五個，適用對象是密閉式一般反應型與快速反應型撒水頭，非側壁型或小區劃型。\n(C) 錯誤。十六與二十是同表「高架儲存倉庫—儲存其他物品」該列的快速反應型十六個、一般反應型二十個。\n(D) 錯誤。二十四與三十是同表「高架儲存倉庫—儲存棉花、塑膠、木製品、紡織品等易燃物品」該列的快速反應型二十四個、一般反應型三十個。\n【記憶點】側壁型與小區劃型只有一組數字：十層以下八個、十一層以上十二個，都是放水二十分鐘。","第 57 條依撒水頭型式分款計算水源容量。第 1 款是密閉式一般反應型、快速反應型，須依表列個數繼續放水二十分鐘；表的內容為：十一樓以上建築物、地下建築物，快速反應型十二個、一般反應型十五個；十樓以下建築物中，供第十二條第一款第四目使用及複合用途建築物中供該目使用者，快速反應型十二個、一般反應型十五個，地下層同為十二個、十五個，其他則為快速反應型八個、一般反應型十個；高架儲存倉庫儲存棉花、塑膠、木製品、紡織品等易燃物品者，快速反應型二十四個、一般反應型三十個，儲存其他物品者，快速反應型十六個、一般反應型二十個。同款但書另定：各類場所實設撒水頭數較應設水源容量之撒水頭數少時，其水源容量得依實際撒水頭數計算之。\n第 2 款是開放式，供第十二條第一款第一目使用場所及第二目集會堂之舞臺，在十層以下建築物之樓層應在最大放水區域全部撒水頭繼續放水二十分鐘之水量以上，在十一層以上建築物之樓層則以最大樓層全部撒水頭計算。第 3 款即本題的側壁型或小區劃型，十層以下八個、十一層以上十二個。第 4 款為放水型撒水頭。可見同一條之內，「幾個撒水頭」隨型式、樓層、用途三個變數變動，作答時務必先鎖定型式，再看樓層。\n放水時間也是易混點，宜逐條並列：自動撒水設備第 57 條各款均為繼續放水二十分鐘；第 36 條室內消防栓設備之水源容量，為裝置室內消防栓最多樓層之全部消防栓繼續放水二十分鐘之水量以上，該樓層消防栓超過二支時以二支計算；第 41 條室外消防栓設備之水源容量，為二具室外消防栓同時放水三十分鐘之水量以上。三者的條號與數值不要互換。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-water-chemical-024","需設置自動撒水設備之場所中，下列何者應設開放式？",24,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-water-chemical-026","固定式泡沫滅火設備之泡沫放出口，若採用高發泡放出口，其泡沫膨脹比應選擇下列何者設置之？",26,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-water-chemical-023","下列場所何者可選擇第二種室內消防栓選擇設置之？",23,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-water-chemical-027","二氧化碳滅火設備之全區放射或局部放射方式防護區域，對放射之滅火藥劑之排放規定，下列何者錯誤？",27,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-water-chemical-022","同一建築基地內有二棟以上建築物時，建築物間外牆與中心線水平距離第一層在 X 公尺以下，第二層在 Y 公尺以下，且合計各棟該第一層及第二層樓地板面積在 Z 平方公尺以上者，應設置消防專用蓄水池。X、Y、Z 分別為何？",22,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-water-chemical-028","消防專用蓄水池規定之有效水量，指蓄水池深度在基地地面下多少公尺範圍內之水量，但採機械方式引水時，不在此限？",28,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-water-chemical-025",111,"泡沫試料淨重為 200 g，還原數值如下，則 25%還原時間為何？時間（分） 0 0.5 1 1.5 2 2.5 3 還原量（ml） 0 10 20 30 40 50 60",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-water-chemical-025",109,"高架倉庫內所設置之撒水頭，其放水量每分鐘應在多少公升以上？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-water-chemical-025",108,"下列何者不屬於各類場所消防安全設備設置標準第 8 條所規定的滅火設備？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-water-chemical-025",107,"泡沫滅火設備進行綜合檢查時，有關泡沫滅火藥劑 25%還原時間標準值敘述，下列何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-water-chemical-025",106,"某一防護對象物長寬高分別為 5 公尺、4 公尺及 1 公尺，若以高發泡局部放射泡沫滅火系統進行防護，依各類場所消防安全設備設置標準之規定，其防護面積應為多少平方公尺？",1785123166757]