[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-110-1-water-chemical-035":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-110-1-水與化學系統消防安全設備概要-035","fire-110-1-water-chemical-035",110,1,35,"依消防安全設備及必要檢修項目檢修基準，製造日期超過 10 年或無法辨識製造日期之何種滅火器，非經水壓測試合格，不得再行更換及充填藥劑，應予報廢？",{"A":16,"B":17,"C":18,"D":19},"機械泡沫滅火器","化學泡沫滅火器","鹵化物滅火器","二氧化碳滅火器","A",null,[],false,"本題考點：《檢修基準》滅火器檢查試樣個數表備註所列，製造日期超過十年須經水壓測試否則報廢的滅火器種類。\n【正解理由】依《消防安全設備及必要檢修項目檢修基準》第一章滅火器性能檢查檢查抽樣之表 1-2 備註，「製造日期超過十年或無法辨識製造日期之水滅火器、機械泡沫滅火器或乾粉滅火器，非經水壓測試合格，不得再行更換及充填藥劑，應予報廢」。四個選項中僅機械泡沫滅火器列名其中，故選 A。\n【逐項排除】\n(A) 機械泡沫滅火器：與備註所列水、機械泡沫、乾粉三者之一相符，為本題應選者。\n(B) 化學泡沫滅火器：不在該備註所列三種之中；其專屬規定是加壓式設置達一年以上者全數受檢、每年實施一次性能檢查，且藥劑與液面標示明顯不符者應予全部更換。\n(C) 鹵化物滅火器：不在該備註之列；表 1-2 對其所定為自製造年份起超過三年以上者受檢，如重量及指示壓力值無異常時，其它項目可予省略。\n(D) 二氧化碳滅火器：不在該備註之列；其重量檢查如失重超過 10％以上或壓力表示值在綠色範圍外時，應予以更新。\n【記憶點】十年報廢門檻只鎖三種：水、機械泡沫、乾粉，非經水壓測試合格不得再行更換及充填藥劑。","這則備註的位置很關鍵：它不是獨立條文，而是附在表 1-2 檢查試樣個數表下方，因此常被只背頻率的考生漏掉。三種被點名的滅火器（水、機械泡沫、乾粉）在表中的受檢對象條件同為「自製造年份起超過三年以上者、全數」，十年則是另一道更高的門檻，跨過後即須以水壓測試作為能否繼續充填的前提。\n相對地，二氧化碳與鹵化物滅火器在表 1-2 的體例不同：受檢對象同為自製造年份起超過三年以上者，但如重量及指示壓力值無異常時，其它項目可予省略；性能檢查注意事項另定，對二氧化碳滅火器及海龍滅火器進行重量檢查時，如失重超過 10％以上或壓力表示值在綠色範圍外，應予以更新。滅火藥劑一節也呼應此點：二氧化碳滅火器及鹵化物滅火器經檢查發現無任何異常現象者，其滅火藥劑之試驗可予省略。\n滅火藥劑的判定方法為應無固化之現象、應無變色、腐敗、沈澱或污損之現象，重量應在表 1-3 總重量容許範圍內（例如藥劑標示重量 1 公斤未滿者為＋100g～－80g，2 公斤以上 5 公斤未滿者為＋300g～－100g，10 公斤以上 20 公斤未滿者為＋700g～－400g）。新更換及充填之滅火藥劑應為經內政部登錄機構認可之產品，充填完成時噴射性能須能噴射所充填滅火藥劑容量或重量 90% 以上之量，使用期限內須能噴射 80% 以上之量；二氧化碳滅火器所充藥劑應採一般工業用之液體二氧化碳，純度應為 99% 以上並有相關證明文件。\n同一基準對「十年」另有一組針對消防水帶（非滅火器）的規定：第二章室內消防栓設備與第七章泡沫滅火設備性能檢查均定，製造年份超過 10 年或無法辨識製造年份之水帶，應施以 7kgf\u002Fcm² 以上水壓試驗 5 分鐘合格始得繼續使用，但已經水壓試驗合格未達 3 年者不在此限。兩者對象不同，不可混記。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-110-1-water-chemical-034","依消防安全設備及必要檢修項目檢修基準，乾粉加壓式滅火器性能檢查之檢查抽樣頻率，應幾年實施一次性能檢查？",34,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-110-1-water-chemical-036","依消防安全設備及必要檢修項目檢修基準，自動撒水設備之加壓送水裝置，在減壓措施方面，補助撒水栓放水壓力應在 X kgf\u002Fcm2 以上 Y kgf\u002Fcm2 以下。X、Y 分別為何？",36,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-110-1-water-chemical-033","依消防安全設備及必要檢修項目檢修基準，滅火器設置間距規定，下列何者錯誤？",33,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-110-1-water-chemical-037","依消防安全設備及必要檢修項目檢修基準，水道連結型自動撒水設備之末端查驗閥或連結之水龍頭等日常生活用水設施配置的壓力表，其放水壓力應在 X kgf\u002Fcm2 以上 Y kgf\u002Fcm2 以下。X、Y 分別為何？",37,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-110-1-water-chemical-032","公共危險物品等場所消防設計及消防安全設備，有關設置冷卻撒水設備規定，下列何者正確？",32,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-110-1-water-chemical-038","依消防安全設備及必要檢修項目檢修基準，海龍滅火設備全區放射方式檢查方法，若以空氣或氮氣進行放射試驗，所需空氣量或氮氣量，應就放射區域應設滅火藥劑量之多少%核算？",38,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-111-1-water-chemical-035",111,"二氧化碳滅火設備採全區放射，其噴頭設置規定下列何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-water-chemical-035",109,"廚房等大量使用火源之處所，多少樓地板面積需有一滅火效能值？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-water-chemical-035",108,"依各類場所消防安全設備檢修及申報作業基準，有關室內消防栓設備呼水裝置之減水警報裝置，當水量減少至多少前應發出警報？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-water-chemical-035",107,"採用移動式放射方式之乾粉滅火設備，藥劑種類為第一種乾粉時，每一具噴射瞄子所需藥劑放射量為：",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-water-chemical-035",106,"乾式比濕式系統的撒水頭數量應追加百分之多少？",1785123166863]