[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-111-1-fire-law-011":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-111-1-消防法規概要-011","fire-111-1-fire-law-011",111,1,11,"有關二氧化碳滅火設備使用之各種標示規格，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"手動啟動裝置標示為紅底白字","放射表示燈點燈時白底紅字","移動放射方式標式白底紅字","音響警報裝置標示黃底黑字","C",null,[],false,"本題考點：二氧化碳滅火設備各種標示之底色與字色規格，其法源為《各類場所消防安全設備設置標準》第 97 條授權中央消防機關另定之標示規格。\n【正解理由】第 97 條明定「二氧化碳滅火設備使用之各種標示規格，由中央消防機關另定之」，據此訂定之《二氧化碳滅火設備各種標示規格》就移動放射方式標式定為紅底白字，與同標準第 96 條第三款「儲存容器近旁設紅色標示燈及標明移動式二氧化碳滅火設備字樣」以紅色為警示基調一致；C 之底色與字色恰好顛倒，為敘述錯誤者，故選 C。\n【逐項排除】\n(A) 手動啟動裝置標示為紅底白字，尺寸Ａ在 300 公釐以上、Ｂ在 100 公釐以上，敘述正確。\n(B) 放射表示燈平時底與字樣均為白色，點燈時為白底紅字，燈具本體為紅色，敘述正確。\n(C) 移動放射方式標式應為紅底白字而非白底紅字，敘述錯誤，為本題應選者。\n(D) 音響警報裝置標示為黃底黑字，須設於室內明顯之處所，每字大小在 25 公釐見方以上，敘述正確。\n【記憶點】手動啟動與移動放射同為紅底白字，放射表示燈點燈才轉紅字，音響警報獨用黃底黑字。","《設置標準》第 97 條把標示規格授權中央消防機關另定，是母法定原則、子規定細節的立法體例；同標準第 98 條並明定乾粉滅火設備之放射方式、通風換氣裝置、防護區域之開口部、選擇閥、啟動裝置、音響警報裝置、安全裝置、緊急電源及各種標示規格，準用第 82 條、第 85 條、第 86 條、第 90 條至第 93 條、第 95 條及第 97 條規定，因此乾粉設備的標示體例與二氧化碳同源，一次記可用於兩處。底色安排有其邏輯：紅色系用於「人要去操作」或「設備所在位置」的標示，故手動啟動裝置與移動放射方式標式同為紅底白字；黃底黑字屬提醒告示，用於音響警報裝置標示，尺寸也最大（Ａ在 480 公釐以上、Ｂ在 270 公釐以上），因為它要讓室內人員在藥劑放射前看懂而退避。放射表示燈則屬燈具，平時底與字樣均為白色，點燈時才呈白底紅字，這正是第 93 條第二款「於防護區域出入口等易於辨認處所設置放射表示燈」的配套；同條第一款另定啟動裝置開關或拉桿開始動作至儲存容器之容器閥開啟，應設二十秒以上之遲延裝置，遲延、警報與表示燈三者構成全區放射方式的安全鏈。延伸考點集中在第 92 條音響警報裝置三款：手動或自動裝置動作後應自動發出警報且藥劑未全部放射前不得中斷、音響警報應有效報知防護區域或防護對象內所有人員、設於全區放射方式者採用人語發音（平時無人駐守者除外）；以及第 82 條第三款移動放射方式之皮管接頭至防護對象任一部分之水平距離在十五公尺以下、第 96 條第五款每一具瞄子之藥劑放射量在溫度攝氏二十度時應在每分鐘六十公斤以上。標示規格題常與這些數值混合命題，記底色字色之外，也要記得數值出自哪一條。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-111-1-fire-law-010","依各類場所消防安全設備檢修期限及申報備查期限，下列敘述何者錯誤？",10,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-111-1-fire-law-012","消防幫浦加壓送水裝置中，有關呼水裝置規定之敘述，下列何者錯誤？",12,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-111-1-fire-law-009","有關室內儲槽場所幫浦設備之設置規定，下列敘述何者錯誤？",9,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-111-1-fire-law-013","某建築物設置收納金屬製避難梯為避難器具，其升降口之施工方法何者錯誤？",13,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-111-1-fire-law-008","可燃性高壓氣體儲存場所防爆牆設置規定，下列何者正確？",8,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-111-1-fire-law-014","下列那一場所不是應設置無線電通信輔助設備之場所？",14,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-fire-law-011",110,"可燃性高壓氣體儲存場所之構造、設備及安全管理相關規定，下列敘述何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-fire-law-011",109,"依各類場所消防安全設備設置標準之規定，下列那一種火警探測器不適合裝設在麵粉廠灰塵會大量滯留的場所？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-fire-law-011",108,"消防設備師及消防設備士參加與消防安全設備設計、監造、裝置及檢修相關技術研討活動之積分證明，下列項目中何者非以每小時積分 10 分累計？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-fire-law-011",107,"依建築技術規則建築設計施工編之規定，所謂的集合住宅，係指具有共同基地及共同空間或設備，並有幾個住宅單位以上之建築物？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-fire-law-011",106,"依據公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法規定，儲存公共危險物品之數量在管制量 20 倍以下者，建築物之一部分在符合相關規定下，得供作室內儲存場所使用，下列何種公共危險物品可儲存於上述之室內儲存場所？",1785123157365]