[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-111-1-water-chemical-022":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-111-1-水與化學系統消防安全設備概要-022","fire-111-1-water-chemical-022",111,1,22,"有關水道連結型自動撒水設備進行綜合檢查時，其放水壓力應為多少？",{"A":16,"B":17,"C":18,"D":19},"0.2 kgf\u002Fcm2 以上 15 kgf\u002Fcm2 以下","0.3 kgf\u002Fcm2 以上 12 kgf\u002Fcm2 以下","0.5 kgf\u002Fcm2 以上 10 kgf\u002Fcm2 以下","0.6 kgf\u002Fcm2 以上 12 kgf\u002Fcm2 以下","C",null,[],false,"本題考點：水道連結型自動撒水設備綜合檢查的放水壓力判定範圍,以及該範圍與一般密閉式撒水設備分屬不同基準。\n【正解理由】依《各類場所消防安全設備設置標準》第 17 條第三項,第一項第九款所定場所樓地板面積合計未達一千平方公尺者,得設置水道連結型自動撒水設備,並明定「水道連結型自動撒水設備設置基準,由中央消防機關定之」;該設備綜合檢查之放水壓力判定範圍為 0.5 kgf\u002Fcm2 以上 10 kgf\u002Fcm2 以下,四個選項中僅上下限同時相符者為 C,故選 C。候選條文未附該設置基準原文,把握度標低。\n【逐項排除】\n(A) 下限 0.2 kgf\u002Fcm2 與上限 15 kgf\u002Fcm2 均非規定值,15 kgf\u002Fcm2 也逾撒水系統放水壓力所定上限。\n(B) 0.3 kgf\u002Fcm2 與 12 kgf\u002Fcm2 都不是該基準所列的判定數值。\n(C) 0.5 kgf\u002Fcm2 以上 10 kgf\u002Fcm2 以下與規定相符,為正解。\n(D) 0.6 kgf\u002Fcm2 之下限與 12 kgf\u002Fcm2 之上限同樣不是規定值。\n【記憶點】水道連結型記 0.5 到 10;《消防安全設備及必要檢修項目檢修基準》自動撒水設備綜合檢查對密閉式撒水設備記 1 到 10,兩組數值各有出處。","水道連結型自動撒水設備是替長照與社福機構量身設計的制度。第 17 條第一項第九款先把榮譽國民之家、長期照顧服務機構(機構住宿式、社區式之建築物使用類組非屬 H-2 之日間照顧、團體家屋及小規模多機能)、老人福利機構(長期照護型、養護型、失智照顧型之長期照顧機構、安養機構)、護理機構(一般護理之家、精神護理之家)、身心障礙福利機構(照顧植物人、失智症、重癱、長期臥床或身心功能退化者)納入應設自動撒水設備之場所;同條第三項再給一條路:這些場所樓地板面積合計未達一千平方公尺者,得設置水道連結型自動撒水設備或與現行法令同等以上效能之滅火設備,或採用中央主管機關公告之措施,其設置基準由中央消防機關另定。因為水源直接連結自來水管路、不另備大型水源與加壓送水裝置,判定用的壓力範圍自成一套。\n一般密閉式的檢查方式可作對照:依《消防安全設備及必要檢修項目檢修基準》自動撒水設備之綜合檢查,先切換成緊急電源供電狀態,於最遠支管末端打開查驗閥確認系統性能,並對加壓送水裝置最近與最遠的末端查驗閥進行放水試驗,幫浦方式與重力水箱、壓力水箱方式的判定均為末端查驗管放水壓力在 1 kgf\u002Fcm2 以上 10 kgf\u002Fcm2 以下。末端查驗閥依第 56 條配置:管徑二十五毫米以上、接裝在各層放水壓力最低之最遠支管末端、一次側設壓力表、二次側設與撒水頭同等放水性能之限流孔、距地板面高度二點一公尺以下並標明字樣。相關考點還有第 50 條撒水頭放水量每分鐘八十公升以上、放水壓力每平方公分一公斤以上。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-111-1-water-chemical-021","下列有關乾粉滅火設備設置之規定，何者正確？",21,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-111-1-water-chemical-023","簡易自動滅火設備進行性能檢查時，蓄壓式滅火藥劑儲存容器滅火藥劑量應與標示差異不超過多少？",23,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-111-1-water-chemical-020","電子工業廠房潔淨室設置消防安全設備，下列敘述何者正確？",20,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-111-1-water-chemical-024","十樓以下建築物之樓層供百貨商場使用，如達到設置自動撒水設備條件，使用密閉式一般反應型撒水頭時，其水源容量應符合幾個撒水頭放水 20 分鐘的撒水量？",24,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-111-1-water-chemical-019","下列有關滅火器性能檢查之敘述，何者正確？",19,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-111-1-water-chemical-025","泡沫試料淨重為 200 g，還原數值如下，則 25%還原時間為何？時間（分） 0 0.5 1 1.5 2 2.5 3 還原量（ml） 0 10 20 30 40 50 60",25,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-water-chemical-022",110,"同一建築基地內有二棟以上建築物時，建築物間外牆與中心線水平距離第一層在 X 公尺以下，第二層在 Y 公尺以下，且合計各棟該第一層及第二層樓地板面積在 Z 平方公尺以上者，應設置消防專用蓄水池。X、Y、Z 分別為何？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-water-chemical-022",109,"室內消防栓之箱面字樣，每字不得小於多少平方公分？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-water-chemical-022",108,"有關潔淨藥劑氣體滅火設備滅火藥劑主要成分之敘述，下列何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-water-chemical-022",107,"可燃性高壓氣體場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽設置滅火器，其設置規定，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-water-chemical-022",106,"下列那一泡沫滅火設備之泡沫濃度，不符泡沫原液與水混合使用濃度之規定？",1785123166313]