[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-111-1-water-chemical-036":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-111-1-水與化學系統消防安全設備概要-036","fire-111-1-water-chemical-036",111,1,36,"二氧化碳滅火設備，採用低壓式滅火藥劑儲存容器時，壓力在何範圍會發出警報？",{"A":16,"B":17,"C":18,"D":19},"23 kgf\u002Fcm2 以上；19 kgf\u002Fcm2 以下","22 kgf\u002Fcm2 以上；19 kgf\u002Fcm2 以下","24 kgf\u002Fcm2 以上；20 kgf\u002Fcm2 以下","21 kgf\u002Fcm2 以上；17 kgf\u002Fcm2 以下","A",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 87 條，二氧化碳滅火設備低壓式儲存容器壓力警報裝置之動作壓力值。\n【正解理由】第 87 條第一項第五款明定「低壓式儲存容器，應設有液面計、壓力表及壓力警報裝置，壓力在每平方公分二十三公斤以上或2.3MPa以上或每平方公分十九公斤以下或1.9MPa以下時發出警報」。警報上限為 23 kgf\u002Fcm² 以上、下限為 19 kgf\u002Fcm² 以下，故選 A。\n【逐項排除】\n(A) 23 kgf\u002Fcm² 以上、19 kgf\u002Fcm² 以下與第 87 條第一項第五款所定完全相符，為本題答案。\n(B) 22 kgf\u002Fcm² 依《消防安全設備及必要檢修項目檢修基準》惰性氣體滅火設備之性能檢查所列動作壓力範圍，係冷凍機啟動之壓力，並非條文所定之壓力上升警報值。\n(C) 24 kgf\u002Fcm² 與 20 kgf\u002Fcm² 於第 87 條第一項第五款均無所據，屬誘答數值。\n(D) 21 kgf\u002Fcm² 依前開檢修基準所列為冷凍機停止之壓力；17 kgf\u002Fcm² 亦非條文所定之下限警報值。\n【記憶點】低壓式二氧化碳警報壓力上 23、下 19（每平方公分公斤）；容器內部溫度維持攝氏零下二十度以上、零下十八度以下。","第 87 條是二氧化碳滅火設備儲存容器的總則條，八款可分成四組掌握。第一組是充填比：高壓式一點五以上一點九以下、低壓式一點一以上一點四以下，同條第二項並定義充填比指容器內容積（公升）與液化氣體重量（公斤）之比值。第二組是儲存場所：應置於防護區域外、置於溫度攝氏四十度以下且溫度變化較少處、不得置於有日光曝曬或雨水淋濕之處。第三組是低壓式專屬裝置：第五款之液面計、壓力表及壓力警報裝置與 23／19 之警報壓力，以及第六款使容器內部溫度維持攝氏零下二十度以上、攝氏零下十八度以下之自動冷凍機。第四組是容器閥與防震：安全裝置符合 CNS 11176、高壓式容器閥符合 CNS 10848 及 10849，容器閥使用電磁閥直接開啟時同時開啟之儲存容器數在七支以上者應設二個以上之電磁閥，並採取有效防震措施。\n低壓式之所以需要壓力警報與自動冷凍機，是因為藥劑以液態低溫儲存，容器內壓必須維持在一段狹窄的常用範圍，壓力偏高有超壓之虞，偏低則代表冷凍功能或藥劑量異常。《消防安全設備及必要檢修項目檢修基準》第十一章惰性氣體滅火設備之性能檢查，就使用低壓二氧化碳氣體之滅火藥劑儲存容器列出完整動作壓力序列供判定：破壞板動作壓力 37 kgf\u002Fcm²、安全閥起噴壓力 25 kgf\u002Fcm²、壓力上升警報 23 kgf\u002Fcm²、冷凍機啟動 22 kgf\u002Fcm²、冷凍機停止 21 kgf\u002Fcm²、壓力下降警報 19 kgf\u002Fcm²，常用壓力範圍即落在其間。設置標準第 87 條第五款所定的 23 與 19，正好對應該序列的上下兩個警報點，其餘數值分屬安全裝置或冷凍機控制，逐一並列比較即可避免張冠李戴。同章外觀檢查另定，低壓式者設於儲存容器之警報用接點壓力表、壓力開關應無變形、損傷等情形，安全裝置、破壞板亦應無損傷或異物阻塞。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-111-1-water-chemical-035","二氧化碳滅火設備採全區放射，其噴頭設置規定下列何者錯誤？",35,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-111-1-water-chemical-037","依規定 112 年度滅火器檢查合格時，應採用那種顏色檢修環？",37,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-111-1-water-chemical-034","第五種滅火設備除滅火器外之其他設備，有關滅火效能值核算之規定，下列何者錯誤？",34,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-111-1-water-chemical-038","一間變壓機房採全區放射二氧化碳滅火設備，其防護區域體積 1250 立方公尺，無其它開口部，此防護區域需要多少二氧化碳藥劑量？",38,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-111-1-water-chemical-033","二氧化碳滅火設備配管，下列設置規定何者錯誤？",33,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-111-1-water-chemical-039","可燃性高壓氣體儲存場所任一點至滅火器之步行距離在 X 公尺以下，並不得妨礙出入作業；每具滅火器對普通火災具有 Y 個以上之滅火效能值，請問前述 X、Y 為何？",39,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-110-1-water-chemical-036",110,"依消防安全設備及必要檢修項目檢修基準，自動撒水設備之加壓送水裝置，在減壓措施方面，補助撒水栓放水壓力應在 X kgf\u002Fcm2 以上 Y kgf\u002Fcm2 以下。X、Y 分別為何？",{"webId":58,"year":59,"stem":60,"number":13},"fire-109-1-water-chemical-036",109,"任一消防專用蓄水池至建築物各部分之水平距離不得超過多少公尺？",{"webId":62,"year":63,"stem":64,"number":13},"fire-108-1-water-chemical-036",108,"依各類場所消防安全設備設置標準之規定，高發泡放出口在全區放射防護區域內，樓地板面積每多少平方公尺應至少設置 1 個，且能有效放射至該區域，並附設泡沫放出停止裝置？",{"webId":66,"year":67,"stem":68,"number":13},"fire-107-1-water-chemical-036",107,"有關自動撒水設備末端查驗閥之敘述，下列何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-106-1-water-chemical-036",106,"低壓式二氧化碳噴頭之放射壓力為每平方公分多少公斤以上？",1785123166462]