[{"data":1,"prerenderedAt":70},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-004":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":53,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-004","fire-112-1-alarm-evacuation-004",112,1,4,"依據一一九火災通報裝置檢修基準之性能檢查，下列何者非預備電源檢查方法之項目？",{"A":16,"B":17,"C":18,"D":19},"端子電壓","信號裝置","切換裝置","結線接續","B",null,[],false,"本題考點：《一一九火災通報裝置檢修基準》性能檢查中，預備電源一項所列的檢查方法項目，考的是能否分辨電源相關項目與通報機能相關項目。\n【正解理由】依《一一九火災通報裝置檢修基準》之性能檢查，預備電源係就電源本身及其供電路徑進行確認，檢查方法包含端子電壓（以三用電表量測電壓是否在規定範圍）、切換裝置（切斷常用電源確認能自動切換至預備電源）與結線接續（確認端子有無鬆動、脫落、腐蝕）等項目。信號裝置屬於通報動作與音響、燈號顯示機能的檢查對象，並非預備電源之檢查項目，故選B。\n【逐項排除】\n(A) 端子電壓是預備電源最基本的檢查方法，用以確認蓄電池容量與充電狀態是否正常，屬預備電源項目。\n(B) 信號裝置關係到通報訊號的發送與顯示機能，歸屬於裝置本體之機能檢查，不在預備電源檢查方法之列，為本題應選的答案。\n(C) 切換裝置檢查常用電源停止時能否自動切換由預備電源供電，恢復時能否自動復歸，是預備電源的核心確認項目。\n(D) 結線接續確認配線端子有無鬆脫、斷線或接續不良，直接影響預備電源能否確實供電，屬預備電源項目。\n【記憶點】預備電源看「電壓、切換、結線」三件事，會發訊號的信號裝置歸機能檢查，不歸電源。","一一九火災通報裝置是把火警訊號自動轉為向消防機關報案的設備，作動後可自動撥號並播放預先錄製的場所地址與名稱語音，也可由現場人員以手動啟動裝置操作。之所以在法制上被強調，是因為長照機構、醫院等避難弱者場所一旦夜間起火，現場往往沒有餘力打電話報案，通報延遲幾分鐘就足以改變傷亡結果，因此《各類場所消防安全設備設置標準》將其列為警報設備之一並指定應設場所，檢修上則由專屬檢修基準規範。\n檢修基準的體例對整個警報系統是共通的，可分為外觀檢查、性能檢查與綜合檢查三層。外觀檢查看得見的部分，如外箱有無變形腐蝕、標示是否脫落、周圍有無妨礙操作之障礙物；性能檢查則拆解為幾個機能單元逐項確認，常見單元包括預備電源、電源、啟動裝置、通報機能、信號裝置、蓄電池等；綜合檢查則模擬實際火災訊號輸入，確認整體連動與通報流程完成。本題的解法關鍵在於認清「預備電源」是一個獨立單元，其檢查方法必然環繞電力本身，也就是電壓夠不夠、切換順不順、線接得牢不牢。\n預備電源與緊急電源是另一組必須分清的概念。預備電源供應設備本身於常用電源中斷時繼續動作所需電力，多以蓄電池構成並附充電裝置；緊急電源則指發電機設備或蓄電池設備等，供應整體消防安全設備於停電時所需電力，容量與供電時間依設備種類另有規定。檢修時端子電壓量測值須與銘板標示比對，切換裝置測試則以切斷常用電源方式確認自動轉換及自動復歸，兩者常一起出題。\n記憶上可用「電壓、切換、結線、充電」四詞概括電源類檢查，凡是題目出現作動音響、顯示燈、通報語音、蓄積時間這類與訊息傳遞有關的字眼，就歸到機能或綜合檢查去，選項一比對即可分流。同一基準還常考手動啟動裝置的設置位置與通報內容應包含之事項，可併同整理。",true,[28,32,36,41,45,49],{"webId":29,"stem":30,"number":12,"year":31,"session":12},"fire-111-1-alarm-evacuation-001","依各類場所消防安全設備設置標準規定，公共危險物品室內儲存場所總樓地板面積在多少平方公尺以上者，應設置火警自動警報設備？",111,{"webId":33,"stem":34,"number":13,"year":35,"session":12},"fire-114-1-alarm-evacuation-004","某電影院放映場所火警自動警報設備所使用之蓄積型偵煙探測器有 10 秒之蓄積時間，其所使用之中繼器有 10 秒之蓄積時間，則其受信總機之蓄積時間，最多可為多少秒？",114,{"webId":37,"stem":38,"number":39,"year":40,"session":12},"fire-110-1-alarm-evacuation-040","避難器具之裝設規定，下列何者正確？",40,110,{"webId":42,"stem":43,"number":12,"year":44,"session":12},"fire-106-1-alarm-evacuation-001","某一 KTV 視聽歌唱場所設於大樓地下層，依規定樓地板面積如合計超過多少，應設置瓦斯漏氣火警自動警報設備？",106,{"webId":46,"stem":47,"number":48,"year":40,"session":12},"fire-110-1-alarm-evacuation-039","依消防安全設備及必要檢修項目檢修基準，火焰式探測器進行性能檢查時，使用火焰探測器用動作試驗器，探測器應在多少時間內動作？",39,{"webId":50,"stem":51,"number":52,"year":44,"session":12},"fire-106-1-alarm-evacuation-002","對於消防安全設備緊急供電系統之配線之規定，下列何者正確？",2,[54,55,58,62,66],{"webId":33,"year":35,"stem":34,"number":13},{"webId":56,"year":40,"stem":57,"number":13},"fire-110-1-alarm-evacuation-004","有一棟總樓地板面積 4,000 平方公尺的七層辦公建築物，當起火層為地上第二層時，下列有關其火警自動警報設備分區鳴動方式的敘述，何者正確？",{"webId":59,"year":60,"stem":61,"number":13},"fire-109-1-alarm-evacuation-004",109,"某火警受信總機設有 15 回路，進行回路能否同時動作測試時，應不要復舊使任意幾回路進行測試？",{"webId":63,"year":64,"stem":65,"number":13},"fire-108-1-alarm-evacuation-004",108,"某一防火構造建築物，地上 5 層且為無開口樓層，1 至 2 層供辦公室用途使用，3 至 5 層供餐廳用途使用，各樓層樓地板面積皆為 200 平方公尺，依照各類場所消防安全設備設置標準之規定，請問本場所火警自動警報設備之設置情形，下列何者正確？",{"webId":67,"year":68,"stem":69,"number":13},"fire-107-1-alarm-evacuation-004",107,"下列那一種探測器，不可以裝設於室內天花板或屋頂板高度 15 公尺以上未滿 20 公尺之空間？",1785123169873]