[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-027":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":50,"hasEssay":68},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-112-1-警報與避難系統消防安全設備概要-027","fire-112-1-alarm-evacuation-027",112,1,27,"依各類場所消防安全設備設置標準之規定，有關緊急電源插座之設置場所與位置規定，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"應設 11 層以上建築物之各樓層","應依建築技術規則應設置之緊急昇降機間","應裝設於樓梯間","每一層任何一處至插座之水平距離在 60 公尺以下","D",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-107-1-alarm-evacuation-023","自居室任一點易於觀察識別其主要出入口，且與主要出入口之步行距離符合規定者，得免設出口標示燈、避難方向指示燈或避難指標，試問下列何者不得免設？",23,107,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-107-1-alarm-evacuation-025","有一飯店，其三樓之樓地板面積為 1200 平方公尺，依各類場所消防安全設備設置標準規定，於設置出口標示燈時，除應使用 A 級或 B 級外，出口標示燈標示面光度應在多少燭光（cd）以上？",25,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-107-1-alarm-evacuation-022","依各類場所消防安全設備設置標準規定，火警自動警報設備之緊急電源，應使用蓄電池設備，其容量能使其有效動作多少分鐘以上？",22,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-107-1-alarm-evacuation-026","依各類場所消防安全設備設置標準規定，緊急供電系統之配線除依屋內線路裝置規則外，有關電源回路之配線耐燃保護，若電線裝於金屬導線管槽內，並埋設於防火構造物之混凝土內，混凝土保護厚度應為多少毫米以上？",26,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-107-1-alarm-evacuation-021","依各類場所消防安全設備設置標準規定，緊急照明設備除內置蓄電池外，應連接緊急電源，其蓄電池容量應能使其持續動作 a 分鐘以上。但採蓄電池設備與緊急發電機併設方式時，其容量應能使其持續動作分別為 b 分鐘及 c 分鐘以上，請問下列何者正確？",21,{"webId":48,"stem":49,"number":13,"year":30,"session":12},"fire-107-1-alarm-evacuation-027","依各類場所消防安全設備設置標準規定，緊急供電系統之配線除依屋內線路裝置規則外，緊急用電源回路及操作回路，應使用多少伏特耐熱絕緣電線，或同等耐熱效果以上之電線？",[51,55,59,63,64],{"webId":52,"year":53,"stem":54,"number":13},"fire-110-1-alarm-evacuation-027",110,"依緊急廣播設備之揚聲器設置規定，廣播區域超過 100 平方公尺時，距揚聲器 1 公尺處所測得之音壓應為多少分貝以上？",{"webId":56,"year":57,"stem":58,"number":13},"fire-109-1-alarm-evacuation-027",109,"有關緩降機支固器具之裝置，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":60,"year":61,"stem":62,"number":13},"fire-108-1-alarm-evacuation-027",108,"依各類場所消防安全設備設置標準第 112 條，有關火警自動警報設備之火警分區劃定規定，下列何者錯誤？",{"webId":48,"year":30,"stem":49,"number":13},{"webId":65,"year":66,"stem":67,"number":13},"fire-106-1-alarm-evacuation-027",106,"避難方向指示燈設於樓梯或坡道者，在樓梯級面或坡道表面之照度，應在多少勒克司（lx）以上？",true,1785123170087]