[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-112-1-water-chemical-017":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":50,"hasEssay":71},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-112-1-水與化學系統消防安全設備概要-017","fire-112-1-water-chemical-017",112,1,17,"有關室內消防栓之水平距離、瞄子放水壓力、消防栓及位置之規定，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"各層任一點至消防栓接頭之水平距離，第一種消防栓在 25 公尺以下、第二種消防栓在 20 公尺以下","消防栓瞄子放水壓力，第一種消防栓在每平方公分 1.7 公斤以上，第二種消防栓在每平方公分 2.5 公斤以上","第一種消防栓配置口徑 38 毫米或 50 毫米之消防栓一個，口徑 38 毫米或 50 毫米、長 15 公尺並附快式接頭之水帶 2 條","供集會或娛樂處所，消防栓設於舞臺二側、觀眾席後二側、包廂前側之位置","C",null,[],false,"",[26,31,35,39,42,46],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-106-1-water-chemical-014","達顯著滅火困難之公共危險物品室外儲存場所，設置室外消防栓設備，其緊急電源應使用發電機設備或蓄電池設備，供電容量應供其有效動作至少多久以上？",14,106,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-106-1-water-chemical-016","自動撒水設備竣工時進行加壓試驗，下列何者正確？",16,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-106-1-water-chemical-013","有關室內消防栓之放水壓力，下列何者錯誤？",13,{"webId":40,"stem":41,"number":13,"year":30,"session":12},"fire-106-1-water-chemical-017","有關撒水頭之設置，下列敘述何者錯誤？",{"webId":43,"stem":44,"number":45,"year":30,"session":12},"fire-106-1-water-chemical-012","簡易自動滅火設備進行性能檢查時，其蓄壓式滅火藥劑量應與標示重量差異在何範圍以內？",12,{"webId":47,"stem":48,"number":49,"year":30,"session":12},"fire-106-1-water-chemical-018","公共危險物品等場所設置自動撒水設備時，使用密閉式撒水頭其水源容量，應在設置 X 個撒水頭繼續放水 Y 分鐘之水量以上，其中 X、Y 分別為：",18,[51,55,59,63,67],{"webId":52,"year":53,"stem":54,"number":13},"fire-111-1-water-chemical-017",111,"惰性氣體滅火設備進行綜合檢查時，採低壓式者進行放射試驗時，其放射試驗所需之藥劑量，為該放射區域所設滅火藥劑量之多少以上？",{"webId":56,"year":57,"stem":58,"number":13},"fire-110-1-water-chemical-017",110,"密閉乾式或預動式之流水檢知裝置二次側配管，為有效排水，支管每 10 公尺傾斜 A 公分，主管每 10 公尺傾斜 B 公分。下列 A，B 何者正確？",{"webId":60,"year":61,"stem":62,"number":13},"fire-109-1-water-chemical-017",109,"某爆竹煙火儲存場所設置室外消防栓設備共 8 具，進行設備檢修綜合檢查時，至少應選擇配管上最遠最高處多少數量之室外消防栓實施放水試驗？",{"webId":64,"year":65,"stem":66,"number":13},"fire-108-1-water-chemical-017",108,"依各類場所消防安全設備檢修及申報作業基準，有關室內消防栓設備之第一種消防栓水帶及瞄子檢查方法，製造年份超過 10 年或無法辨識製造年份之水帶，應將消防水帶兩端之快速接頭連接於耐水壓試驗機，施以 X kgf\u002Fcm2 以上水壓試驗 Y 分鐘合格，始得繼續使用。則 X+Y 為若干？",{"webId":68,"year":69,"stem":70,"number":13},"fire-107-1-water-chemical-017",107,"一電氣設備室長寬高分別為 12 m、8 m 及 4 m，若採二氧化碳全區放射滅火設備防護，藥劑放射後採機械排放，則其排風機之風量應為每分鐘多少立方公尺？",true,1785123165832]