[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-113-1-alarm-evacuation-022":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":50,"hasEssay":68},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-113-1-警報與避難系統消防安全設備概要-022","fire-113-1-alarm-evacuation-022",113,1,22,"某建築物設有火警受信總機 50 回路，竣工時實施性能試驗，於進行受信總機同時動作試驗時，使用常用電源，應將任意 X 回路設定在火警動作狀態；使用預備電源，應將任意 Y 回路設定在火警動作狀態，判定受信總機、主音響裝置、地區音響裝置、附屬裝置等性能應無異常。則 X+Y=？",{"A":16,"B":17,"C":18,"D":19},"5","6","7","8","C",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-108-1-alarm-evacuation-018","利用加瓦斯試驗器對瓦斯漏氣檢知器進行檢測，其性能判定方法下列何者錯誤？",18,108,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-108-1-alarm-evacuation-020","依消防法令規定，觀光旅館、飯店、旅館、招待所（限有寢室客房者）等場所，採膠囊式經營時，須設置火警自動警報設備者，下列何者錯誤？",20,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-108-1-alarm-evacuation-017","某商場有一樓層，以防煙垂壁區劃為四區，各區劃樓地板面積分別為 100 平方公尺、300 平方公尺、250 平方公尺、200 平方公尺，採用機械排煙方式，四區劃僅設置 1 台排煙風機，試問該排煙風機之排煙量每分鐘不得小於多少立方公尺？",17,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-108-1-alarm-evacuation-021","依各類場所消防安全設備設置標準規定，下列危險物品場所何者不須設置火警自動警報設備？",21,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-108-1-alarm-evacuation-016","依照各類場所消防安全設備檢修及申報作業基準之規定，某燃燒器具的瓦斯，對空氣比重大於 1 時，其檢知器應設於距瓦斯燃燒器具或瓦斯導管貫穿牆壁處水平距離 A 公尺以內；檢知器上端，應裝設在距樓地板面 B 公分範圍內。請問前述 A、B 為何？",16,{"webId":48,"stem":49,"number":13,"year":30,"session":12},"fire-108-1-alarm-evacuation-022","依照各類場所消防安全設備檢修及申報作業基準之規定，會結露之場所適用的探測器為下列何者？",[51,55,59,60,64],{"webId":52,"year":53,"stem":54,"number":13},"fire-110-1-alarm-evacuation-022",110,"有一地下 3 層、地上 7 層之建築物，各層樓地板面積為 600 平方公尺，若地下 1 樓發生火警，則火警自動警報設備之鳴動樓層，下列何者正確？",{"webId":56,"year":57,"stem":58,"number":13},"fire-109-1-alarm-evacuation-022",109,"有關使用瓦斯之場所供各類場所消防安全設備設置標準第 12 條第 5 款第 1 目使用之地下層，其樓地板面積合計 X 平方公尺以上，且其中甲類場所樓地板面積合計 Y 平方公尺以上者，應設置瓦斯漏氣火警自動警報設備，下列何者與該設置標準之規定相同？",{"webId":48,"year":30,"stem":49,"number":13},{"webId":61,"year":62,"stem":63,"number":13},"fire-107-1-alarm-evacuation-022",107,"依各類場所消防安全設備設置標準規定，火警自動警報設備之緊急電源，應使用蓄電池設備，其容量能使其有效動作多少分鐘以上？",{"webId":65,"year":66,"stem":67,"number":13},"fire-106-1-alarm-evacuation-022",106,"依出口標示燈及避難方向指示燈認可基準規定，燈具附有起動器者，應在多少時間內點燈？",true,1785123169672]