[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-113-1-alarm-evacuation-024":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":50,"hasEssay":68},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-113-1-警報與避難系統消防安全設備概要-024","fire-113-1-alarm-evacuation-024",113,1,24,"依各類場所消防安全設備設置標準規定，有關引導燈具與緊急照明燈之照度規定，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"避難方向指示燈設於樓梯或坡道者，在樓梯級面或坡道表面之照度，應在 1 勒克司（Lux）以上","觀眾席引導燈之照度，在觀眾席通道地面之水平面上測得之值，在 0.5 勒克司（Lux）以上","緊急照明燈在地面之水平面照度，地下建築物之地下通道，其地板面應在 10 勒克司（Lux）以上","緊急照明燈在地面之水平面照度，其他場所，其地板面應在 2 勒克司（Lux）以上","B",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-108-1-alarm-evacuation-020","依消防法令規定，觀光旅館、飯店、旅館、招待所（限有寢室客房者）等場所，採膠囊式經營時，須設置火警自動警報設備者，下列何者錯誤？",20,108,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-108-1-alarm-evacuation-022","依照各類場所消防安全設備檢修及申報作業基準之規定，會結露之場所適用的探測器為下列何者？",22,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-108-1-alarm-evacuation-019","應設排煙設備場所之樑為裸露式者，交錯之樑形成之各防煙區劃皆應設置排煙口。但其樓地板面積每 500 平方公尺防煙區劃內，防煙壁及排煙口之設置，符合各類場所消防安全設備設置標準第 188 條第 1 項第 3 款規定，並符合下列何者，不在此限？〔A：大樑深度（cm）；B：中樑深度（cm）；X：大樑下加設之垂壁高度（cm），其值得為 0；A＋X：防煙壁下垂高度（cm）。〕",19,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-108-1-alarm-evacuation-023","偵煙式局限型探測器裝設於防火構造建築物天花板高度 8 公尺之裝置面時，若樓地板面積為 500 平方公尺，且其天花板中間有一下垂 40 公分的樑隔開，試問至少須設置幾個偵煙式局限型 1 種探測器？",23,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-108-1-alarm-evacuation-018","利用加瓦斯試驗器對瓦斯漏氣檢知器進行檢測，其性能判定方法下列何者錯誤？",18,{"webId":48,"stem":49,"number":13,"year":30,"session":12},"fire-108-1-alarm-evacuation-024","某防火構造建築物，供三溫暖洗澡區使用，面積為 130 m2，天花板高度為 3.6 m，請問下列何者為適當的探測器？",[51,55,59,60,64],{"webId":52,"year":53,"stem":54,"number":13},"fire-110-1-alarm-evacuation-024",110,"差動式分布型探測器採熱電偶式時，下列敘述何者錯誤？",{"webId":56,"year":57,"stem":58,"number":13},"fire-109-1-alarm-evacuation-024",109,"有關標示設備設在避難出口避難指標之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":48,"year":30,"stem":49,"number":13},{"webId":61,"year":62,"stem":63,"number":13},"fire-107-1-alarm-evacuation-024",107,"P 型受信總機採用數個分區共用一公用線方式配線時，該公用線供應之分區數，依各類場所消防安全設備設置標準規定，不得超過多少個？",{"webId":65,"year":66,"stem":67,"number":13},"fire-106-1-alarm-evacuation-024",106,"依各類場所消防安全設備設置標準規定，特別安全梯或緊急昇降機間排煙室之排煙設備設置排煙、進風風管時，下列何者有誤？",true,1785123169686]