[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-113-1-alarm-evacuation-025":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":50,"hasEssay":68},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-113-1-警報與避難系統消防安全設備概要-025","fire-113-1-alarm-evacuation-025",113,1,25,"依各類場所消防安全設備設置標準之規定，有關緊急電源插座之設置規定，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"每一層任何一處至插座之步行距離在 50 公尺以下","插座電流供應容量為交流單相 110 伏特 15 安培，其容量約為 1.5 瓩以上","裝設高度距離樓地板 0.8 公尺以上 1.5 公尺以下","應從主配電盤設專用回路，各層至少設 1 回路以上之供電線路，且每回路之連接插座數在 10 個以下","B",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-108-1-alarm-evacuation-021","依各類場所消防安全設備設置標準規定，下列危險物品場所何者不須設置火警自動警報設備？",21,108,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-108-1-alarm-evacuation-023","偵煙式局限型探測器裝設於防火構造建築物天花板高度 8 公尺之裝置面時，若樓地板面積為 500 平方公尺，且其天花板中間有一下垂 40 公分的樑隔開，試問至少須設置幾個偵煙式局限型 1 種探測器？",23,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-108-1-alarm-evacuation-020","依消防法令規定，觀光旅館、飯店、旅館、招待所（限有寢室客房者）等場所，採膠囊式經營時，須設置火警自動警報設備者，下列何者錯誤？",20,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-108-1-alarm-evacuation-024","某防火構造建築物，供三溫暖洗澡區使用，面積為 130 m2，天花板高度為 3.6 m，請問下列何者為適當的探測器？",24,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-108-1-alarm-evacuation-019","應設排煙設備場所之樑為裸露式者，交錯之樑形成之各防煙區劃皆應設置排煙口。但其樓地板面積每 500 平方公尺防煙區劃內，防煙壁及排煙口之設置，符合各類場所消防安全設備設置標準第 188 條第 1 項第 3 款規定，並符合下列何者，不在此限？〔A：大樑深度（cm）；B：中樑深度（cm）；X：大樑下加設之垂壁高度（cm），其值得為 0；A＋X：防煙壁下垂高度（cm）。〕",19,{"webId":48,"stem":49,"number":13,"year":30,"session":12},"fire-108-1-alarm-evacuation-025","依各類場所消防安全設備設置標準規定，火警自動警報設備之火警發信機（非定址式）與 P 型受信總機，其配線為何種配線？",[51,55,59,60,64],{"webId":52,"year":53,"stem":54,"number":13},"fire-110-1-alarm-evacuation-025",110,"下列有關火警受信總機之裝置規定，何者錯誤？",{"webId":56,"year":57,"stem":58,"number":13},"fire-109-1-alarm-evacuation-025",109,"有關火焰式探測器之設置，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":48,"year":30,"stem":49,"number":13},{"webId":61,"year":62,"stem":63,"number":13},"fire-107-1-alarm-evacuation-025",107,"有一飯店，其三樓之樓地板面積為 1200 平方公尺，依各類場所消防安全設備設置標準規定，於設置出口標示燈時，除應使用 A 級或 B 級外，出口標示燈標示面光度應在多少燭光（cd）以上？",{"webId":65,"year":66,"stem":67,"number":13},"fire-106-1-alarm-evacuation-025",106,"依緊急照明燈認可基準規定，內置電池型緊急電源供電照明時間應維持 1.5 小時以上（供緊急照明燈總數）後，其蓄電池電壓不得小於蓄電池額定電壓多少百分比？",true,1785123169700]