[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-113-1-fire-law-019":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":50,"hasEssay":68},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-113-1-消防法規概要-019","fire-113-1-fire-law-019",113,1,19,"已領有消防設備人員證書並具有 2 年以上消防實務經驗者，應向主管機關提出申請登記及核發執業執照，始得執行業務。有關消防實務經驗，下列何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"曾於消防設備人員法第 7 條第 1 項規定之事務所、公司、有限合夥、商業、其他專業機構、工程技術顧問公司實際參與消防安全設備技術或工程執行工作","曾於政府機關（構）、公立學校、公營事業機構及公法人，未經消防設備師、消防設備士或其他具適當指導資格人員指導，獨立執行消防安全設備技術或工程工作","曾任專科以上學校教授、副教授、助理教授或講師，並講授消防安全設備技術或工程學科 2 門主科","曾於各級消防機關從事消防安全設備圖說審查、竣工查驗或安全檢查工作","B",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-107-1-fire-law-015","依各類場所消防安全設備檢修及申報作業基準之規定，進行密閉式撒水設備綜合檢查時，當以幫浦方式作為加壓送水裝置時，末端查驗管之放水壓力應在 a kgf／cm2 以上、b kgf／cm2 以下。a、b 各為何值？",15,107,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-107-1-fire-law-017","依各類場所消防安全設備檢修及申報作業基準之規定，瓦斯漏氣檢知器的設置位置，當瓦斯對空氣之比重未滿 1 時，檢知器下端，應裝設在天花板下方 a 公分範圍內；瓦斯對空氣之比重大於 1 時，檢知器上端，應裝設在距樓地板面 b 公分範圍內。a、b 各為何值？",17,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-107-1-fire-law-014","依各類場所消防安全設備檢修及申報作業基準之規定，滅火器本體上端與樓地板面之距離，若滅火器未滿 18 公斤者應在多少公尺以下？",14,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-107-1-fire-law-018","依各類場所消防安全設備檢修及申報作業基準之規定，供第四類公共危險物品之顯著滅火困難場所之冷卻撒水設備的加壓送水裝置，除非設有保壓措施，否則，啟動後 a 分鐘內應能有效撒水，且加壓送水裝置距撒水區域在 b 公尺以下。a、b 各為何值？",18,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-107-1-fire-law-013","依各類場所消防安全設備檢修及申報作業基準之規定，各類場所之管理權人應於檢修完成後幾日內，分別填具消防安全設備檢修申報表及檢附消防安全設備檢修報告書，向當地消防機關申報？",13,{"webId":48,"stem":49,"number":13,"year":30,"session":12},"fire-107-1-fire-law-019","依各類場所消防安全設備檢修及申報作業基準之規定，有關室內消防栓加壓送水裝置的減壓措施性能檢查，若公共危險物品等場所達顯著滅火困難者設置之第一種滅火設備之消防栓，其放水壓力應在 a kgf\u002Fcm2 以上、b kgf\u002Fcm2 以下。a、b 各為何值？",[51,55,59,63,67],{"webId":52,"year":53,"stem":54,"number":13},"fire-111-1-fire-law-019",111,"依各類場所消防安全設備設置標準第 12 條之場所用途分類，下列何者錯誤？",{"webId":56,"year":57,"stem":58,"number":13},"fire-110-1-fire-law-019",110,"有一棟建築物高度超過 60 公尺，其連結送水管採用濕式設計，並設中繼幫浦，下列敘述何者正確？",{"webId":60,"year":61,"stem":62,"number":13},"fire-109-1-fire-law-019",109,"依可燃性高壓氣體儲存場所防爆牆設置基準之規定，防爆牆長度應超過設置方位儲存場所建築物牆面長度，其牆腳與儲存場所建築物之距離不得少於多少公尺？",{"webId":64,"year":65,"stem":66,"number":13},"fire-108-1-fire-law-019",108,"下列何者非各類場所消防安全設備設置標準所規定之甲類場所？",{"webId":48,"year":30,"stem":49,"number":13},true,1785123156546]