[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-114-1-alarm-evacuation-016":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":50,"hasEssay":68},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-114-1-警報與避難系統消防安全設備概要-016","fire-114-1-alarm-evacuation-016",114,1,16,"依各類場所消防安全設備設置標準，出口標示燈及避難方向指示燈之緊急電源之設置規定，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"總樓地板面積在 1 萬平方公尺以上高層建築物，通往直通樓梯之出入口的出口標示燈，該緊急電源容量應在 60 分鐘以上","地下建築物，其總樓地板面積在 1 千平方公尺以上者，由室內往走廊或通道之出入口標示燈，該緊急電源容量應在 60 分鐘以上","總樓地板面積在 5 萬平方公尺以上建築物的直通樓梯，其避難方向指示燈之緊急電源容量應在 60 分鐘以上","樓高在 100 公尺以上建築物，總樓地板面積在 1 萬平方公尺以上，通往直通樓梯之出入口的避難方向指示燈，該緊急電源容量應在 60 分鐘以上","C",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-109-1-alarm-evacuation-012","有關緊急電源插座之設置規定，下列敘述何者正確？",12,109,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-109-1-alarm-evacuation-014","某百貨商場之 5 樓樓地板面積為 2,100 平方公尺，依各類場所消防安全設備設置標準規定，該層樓至少應設置幾個防煙區劃？",14,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-109-1-alarm-evacuation-011","避難器具設置數量需衡酌場所之收容人數，依各類場所消防安全設備設置標準規定，百貨商場供飲食或休息用場所之收容人數計算，應以該部分樓地板面積除多少？",11,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-109-1-alarm-evacuation-015","有關排煙設備之設置規定，下列敘述何者錯誤？",15,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-109-1-alarm-evacuation-010","緩降機之設置應保有必要操作面積（不含避難器具所占面積），其相關規定下列何者正確？",10,{"webId":48,"stem":49,"number":13,"year":30,"session":12},"fire-109-1-alarm-evacuation-016","防煙壁為自天花板下垂 X 公分以上之垂壁，但地下建築物之地下通道，防煙壁應自天花板下垂 Y 公分以上，其中 X、Y 分別為：",[51,55,56,60,64],{"webId":52,"year":53,"stem":54,"number":13},"fire-110-1-alarm-evacuation-016",110,"建築物之避難器具設置緩降機時，對其開口部進行外觀檢查之判定，下列何者合格？",{"webId":48,"year":30,"stem":49,"number":13},{"webId":57,"year":58,"stem":59,"number":13},"fire-108-1-alarm-evacuation-016",108,"依照各類場所消防安全設備檢修及申報作業基準之規定，某燃燒器具的瓦斯，對空氣比重大於 1 時，其檢知器應設於距瓦斯燃燒器具或瓦斯導管貫穿牆壁處水平距離 A 公尺以內；檢知器上端，應裝設在距樓地板面 B 公分範圍內。請問前述 A、B 為何？",{"webId":61,"year":62,"stem":63,"number":13},"fire-107-1-alarm-evacuation-016",107,"避難器具之設置數量與場所之收容人數有很大的關係，依各類場所消防安全設備設置標準規定，有關醫療機構（醫院、診所）候診室之收容人數之計算，應以各候診室之樓地板面積和除多少平方公尺所得之數，做為候診室之收容人數？",{"webId":65,"year":66,"stem":67,"number":13},"fire-106-1-alarm-evacuation-016",106,"瓦斯漏氣火警自動警報設備裝置於瓦斯對空氣之比重未滿一之建築物室內時，檢知器設置位置應距瓦斯燃燒器具或瓦斯導管貫穿牆壁處水平距離多少以內？",true,1785123169225]