[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-115-1-alarm-evacuation-016":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":50,"hasEssay":68},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-115-1-警報與避難系統消防安全設備概要-016","fire-115-1-alarm-evacuation-016",115,1,16,"超過 100 公尺的某大樓，其地下層應設無線電通信輔助設備使用洩波同軸電纜，依設置規定，下列何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"在任一出入口與其他出入口之步行距離大於 300 公尺時，必須設置 1 個接頭","設於距樓地板面或基地地面高度 0.8 公尺至 1.5 公尺間","該電纜適合傳送或輻射 150 百萬赫（Mhz），保護箱內設長度 2 公尺以上之射頻電纜","洩波同軸電纜之標稱阻抗為 50 歐姆","A",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-110-1-alarm-evacuation-012","建築物某一樓層（A 區）通往直通樓梯（B 區）的出口標示燈（L）附有誘導音裝置，並設置有停止專用偵煙式探測器（D）及具有緊急廣播設備連動停止性能，在其性能試驗之連動停止試驗中，下列何者應判定不合格？",12,110,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-110-1-alarm-evacuation-014","對火警自動警報設備二信號式受信總機進行火災表示之性能檢查時，接到第 1 報火警信號但尚未接到第 2 報火警信號時，下列那二種裝置均不應動作？",14,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-110-1-alarm-evacuation-011","特別安全梯間與緊急昇降機間兼用之排煙室，如設置排煙管道及進風管道，下列何者在綜合試驗中應判定合格？",11,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-110-1-alarm-evacuation-015","對空氣管式之差動式分布型探測器進行空氣注入之性能檢查時，下列何種試驗無須量測探測器導通與否？",15,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-110-1-alarm-evacuation-010","各型探測器在性能試驗中，下列有關其動作試驗的動作時間，何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",10,{"webId":48,"stem":49,"number":13,"year":30,"session":12},"fire-110-1-alarm-evacuation-016","建築物之避難器具設置緩降機時，對其開口部進行外觀檢查之判定，下列何者合格？",[51,52,56,60,64],{"webId":48,"year":30,"stem":49,"number":13},{"webId":53,"year":54,"stem":55,"number":13},"fire-109-1-alarm-evacuation-016",109,"防煙壁為自天花板下垂 X 公分以上之垂壁，但地下建築物之地下通道，防煙壁應自天花板下垂 Y 公分以上，其中 X、Y 分別為：",{"webId":57,"year":58,"stem":59,"number":13},"fire-108-1-alarm-evacuation-016",108,"依照各類場所消防安全設備檢修及申報作業基準之規定，某燃燒器具的瓦斯，對空氣比重大於 1 時，其檢知器應設於距瓦斯燃燒器具或瓦斯導管貫穿牆壁處水平距離 A 公尺以內；檢知器上端，應裝設在距樓地板面 B 公分範圍內。請問前述 A、B 為何？",{"webId":61,"year":62,"stem":63,"number":13},"fire-107-1-alarm-evacuation-016",107,"避難器具之設置數量與場所之收容人數有很大的關係，依各類場所消防安全設備設置標準規定，有關醫療機構（醫院、診所）候診室之收容人數之計算，應以各候診室之樓地板面積和除多少平方公尺所得之數，做為候診室之收容人數？",{"webId":65,"year":66,"stem":67,"number":13},"fire-106-1-alarm-evacuation-016",106,"瓦斯漏氣火警自動警報設備裝置於瓦斯對空氣之比重未滿一之建築物室內時，檢知器設置位置應距瓦斯燃燒器具或瓦斯導管貫穿牆壁處水平距離多少以內？",true,1785123168840]