[{"data":1,"prerenderedAt":69},["ShallowReactive",2],{"q-fire-115-1-fire-law-037":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":50,"hasEssay":68},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-115-1-消防法規概要-037","fire-115-1-fire-law-037",115,1,37,"各類場所設置滅火器之設置間距，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"設有滅火器之樓層或場所，自樓面居室任一點至滅火器之步行距離不得超過 20 公尺","公共危險物品場所達顯著滅火困難者，設置之大型滅火器，距防護對象任一點之步行距離，應在 30 公尺以下","公共危險物品場所達一般滅火困難者，設置之大型滅火器，距防護對象任一點之步行距離，應在 30 公尺以下","設有滅火器之可燃性高壓氣體儲存場所，任一點至滅火器之步行距離應在 30 公尺以下，並不得妨礙出入作業","D",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-109-1-fire-law-033","依各類場所消防安全設備檢修及申報作業基準之規定，各類場所之管理權人應委託檢修專業機構或消防法第 7 條規定之人員辦理檢修，並於檢修完成後多少日內，分別填具消防安全設備檢修申報表及檢附消防安全設備檢修報告書，向當地消防機關申報？",33,109,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-109-1-fire-law-035","依消防幫浦加壓送水裝置等及配管摩擦損失計算基準之規定，裝設消防撒水幫浦，設計水量為 600 公升\u002F分，其設計揚程為 50 公尺；當揚水量在 900 公升\u002F分時，其揚程需調校在下列何標準值以上，方能判定合格？",35,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-109-1-fire-law-032","依各類場所消防安全設備檢修及申報作業基準，有關滅火器外觀檢查之規定，滅火器本體上端與樓地板面之距離，18 公斤以上者不得超過 a 公尺，未滿 18 公斤者不得超過 b 公尺。a、b 值各為下列何者？",32,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-109-1-fire-law-036","依避難器具支固器具及固定部之結構、強度計算及施工方法之規定，裝置避難器具固定部材料，使用直徑 1 公分錨定螺栓，設定試驗荷重 500 公斤力（kgf）時，則鎖緊扭力應為多少公斤力\u002F公分（kgf\u002Fcm）？",36,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-109-1-fire-law-031","依各類場所消防安全設備設置標準，有關泡沫原液儲存量、泡沫原液與水混合使用濃度之規定，下列敘述何者正確？",31,{"webId":48,"stem":49,"number":13,"year":30,"session":12},"fire-109-1-fire-law-037","依建築技術規則建築設計施工編之定義，每層陽臺面積之和，以不超過建築面積多少為限？其未達 8 平方公尺者，得建築 8 平方公尺。",[51,55,59,60,64],{"webId":52,"year":53,"stem":54,"number":13},"fire-111-1-fire-law-037",111,"依據乾粉滅火設備各種標示規格規定，其標示規格為長 480 mm 以上，寬 270 mm 以上，黃底黑字，每字大小為 25 mm×25 mm 以上，係屬下列何者？",{"webId":56,"year":57,"stem":58,"number":13},"fire-110-1-fire-law-037",110,"有關二氧化碳滅火設備使用之各種標示規格，下列敘述何者正確？",{"webId":48,"year":30,"stem":49,"number":13},{"webId":61,"year":62,"stem":63,"number":13},"fire-108-1-fire-law-037",108,"依避難器具支固器具及固定部之結構、強度計算及施工方法規定，裝置避難器具之固定部，應能承受承載荷重與附加荷重之和。若避難器具為緩降機，其承載荷重應為最大使用人數乘以多少？",{"webId":65,"year":66,"stem":67,"number":13},"fire-107-1-fire-law-037",107,"依防火牆及防火水幕設置基準之規定，有一儲槽其水平剖面最大半徑為 5 公尺，內裝有公共危險物品，該公共危險物品之閃火點為攝氏八十度，則假想火面高度為多少公尺？",true,1785123155795]